NOTE: the "normal operating temp" means the avg temp of the hashboard(s). There might be 2 temps displayed on miner dashboard in some miner versions; on the left is the avg temp of the chips, and on the right is the avg temp of the hashboard.
We only need to focus on the temperature on the right side, which is the hashboard temperature.
It is advisable to provide the miner with a good cooling environment for optimal performance. Proper heat dissipation can help prevent overheating and ensure the miner operates within its specified temperature range. This can be achieved by ensuring proper ventilation, adequate airflow, and keeping the surroundings free from dust or obstructions that may hinder heat dissipation.
Goldshell BYTE
| Miner Model | Normal operating temperature/temperature range (℃) | The temperature threshold that triggers over-temperature protection. |
| Goldshell BYTE | 65~75 | 85 |
ECHO Series Miners
| Miner Model | Normal operating temperature/temperature range (℃) | The temperature threshold that triggers over-temperature protection. |
| E-KA1M | 75~80 | 88 |
| E-DG1M | 75~80 | 90 |
| E-AL1M | 75~80 | 88 |
| E-AE1M | 75~80 | 88 |
BOX Series Miners
| Miner Model | Normal operating temperature/temperature range (℃) | The temperature threshold that triggers over-temperature protection. |
| AE BOX | 55~60 | 80~90 |
| AE BOX PRO | 55~60 | 80~90 |
| AE BOX Ⅱ | 55-60 | 80-90 |
| KA BOX | 72~80 | 98 |
| KA BOX PRO | 75~85 | 89 |
| AL BOX | 65~75 | 95 |
| AL BOX Ⅱ | 70~80 | 95 |
| AL BOX Ⅱ+ | 78 | 88 |
| MINI DOGE Ⅲ | 75~80 | 89 |
| MINI DOGE Ⅲ+ | 65~75 | 86 |
| MINI DOGE | 78 | 95 |
| MINI DOGE PRO | 78 | 95 |
| MINI DOGE Ⅱ | 78 | 95 |
| HS BOX | 70 | 85 |
| SC BOX | 65 | 85 |
| SC BOX Ⅱ | 77 | 86 |
| CK BOX | 70 | 88 |
| CK BOX Ⅱ | 78 | 86 |
| KD BOX | 70 | 86 |
| KD BOX PRO | 75 | 86 |
| KD BOX Ⅱ | 78 | 86 |
| LB BOX | 80 | 98 |
| STC BOX | 60 | 95 |
MAX Series Miners
| Miner Model | Normal operating temperature/temperature range (℃) | The temperature threshold that triggers over-temperature protection. |
| X5 | 55 | 75 |
| LT5 | 65 | 90 |
| LT5 PRO | 78 | 95 |
| LT6 | 78 | 95 |
| HS5 | 70 | 85 |
| HS3 | 72 | 85 |
| HS3 SE | 65 | 85 |
| HS6 | 70 | 85 |
| SC6 SE | 70 | 88 |
| CK5 | 65 | 85 |
| CK6 | 79 | 99 |
| KD2 | 65 | 85 |
| KD5 | 72 | 90 |
| KD6 | 75 | 85 |
| KD6 SE | 78 | 88 |
| KD MAX | 75 | 85 |
LITE Series Miners
| Miner Model | Normal operating temperature/temperature range (℃) | The temperature threshold that triggers over-temperature protection. |
| HS LITE | 77 | 92 |
| CK LITE | 75 | 90 |
| KD LITE | 76 | 89 |
| SC LITE | ||
| LT LITE | ||
| LB LITE |